Optimization of high-performance flexible thermoelectric generator from material synthesis to simulation and device application
ENERGY CONVERSION AND MANAGEMENT, no.291, pp.1-11, 2023 (SCI-Expanded, Scopus)
- Publication Type: Article / Article
- Publication Date: 2023
- Doi Number: 10.1016/j.enconman.2023.117335
- Journal Name: ENERGY CONVERSION AND MANAGEMENT
- Journal Indexes: Applied Science & Technology Source, Scopus, Aerospace Database, Science Citation Index Expanded (SCI-EXPANDED), Academic Search Premier, PASCAL, Communication Abstracts, Computer & Applied Sciences, Environment Index, INSPEC, CAB Abstracts, Pollution Abstracts, Veterinary Science Database, Civil Engineering Abstracts
- Page Numbers: pp.1-11
- Istanbul University-Cerrahpasa Affiliated: Yes
Abstract
Recently, flexible thermoelectric (f-TEG) power generators have attracted great attention due to their ability to
capture waste heat from curved heat sources and convert it into useful electrical power. This study presents the
material synthesis, theoretical optimization, module fabrication, and device application of a high-performance fTEG. Firstly, n-type Bi2Te2.7Se0.3 and p-type Sb1.5Bi0.5Te3 TE materials were synthesized via a low-cost and fast
fabrication process of mechanical alloying, cold pressed followed by a sintering process. The n-type and p-type
materials exhibit maximum ZT values of 0.7 and 1.1, respectively. Then, the transport properties were used to
optimize the geometry of the f-TEG in COMSOL Multiphysics. Based on the optimized parameters, a flexible
module was developed which consists of 70 thermocouples each has a leg dimension of 1 × 1.5 × 2 mm3
. The
fabricated f-TEG measured on the arm generates an open circuit voltage, and power output of 93 mV, and 556
µW, respectively, at a temperature difference of 10 ◦C. The device was tested with a custom-made two-wire
wireless ECG (electrocardiogram) and TEG harvester. Charge and discharge times of the supercapacitor and the
efficiency of the TEG harvester were determined for the temperature difference of 10 ◦C. The test results show
that the f-TEG can generate enough power to supply energy to the wireless ECG, but the efficiency of the boost
converter is as low as 20%.